Product type: Optical Filter. Application: Lighting, Medical, Optical, Photography, Astronomy. Model: Filter.
Overview
The 18mm Od2 546nm Coated Optical Fluorescence Filter is supplied as a bandpass filter made from Glass. Listed geometry: diameter 18.0+0.0/-0.3mm, size Mitutoyo Vernier caliper, thickness 1.0+/-0.1mm. Optical / electrical data: transmittance 200-1000nm,AOI:0deg. Coating: OD2+/-0.1 at 546nm; surface quality 60-40. Typical applications: Lighting, Medical, Optical, Photography and Astronomy. Dimensions, material grade, coating and finish can be quoted to your drawing; the values above are the listed starting point.
Specifications
| Material | Glass |
|---|---|
| Type | Optical Filter |
| Shape | Customized |
| Diameter | 18.0+0.0/-0.3mm |
| Thickness | 1.0+/-0.1mm |
| Coating | OD2+/-0.1 at 546nm |
| Surface quality | 60-40 |
| Parallelism | <1arcmin |
| Clear aperture | >D16mm |
| Usage | Lighting, Medical, Optical, Photography, Astronomy |
| Model NO. | Filter |
| Thickness Range | 0.5mm-1mm |
| Color | Transparent |
| Principle | Optical Filter |
| Angle of incidence | 0° |
| Specifications | Description |
| R1 | infinity |
| R2 | infinity |
| Chamfer | 0.25mmx45deg |
| Maximum OD | 2.8OD |
| Minimum OD | 1.7OD |
| Transmission band | 200-1000nm,AOI:0deg |
| Standard | MIL-PER-13830B |
| Inspection | Parameters |
| Dimensions | Mitutoyo Vernier caliper |
| Supplier | CPG OPTICS LIMITED |
Technical data
| Description | |
|---|---|
| Material: | UVFS |
| Diameter: | 18.0+0.0/-0.3mm |
| Thickness: | 1.0+/-0.1mm |
| R1: | infinity |
| R2: | infinity |
| Flatness: | N/A |
| Surface quality: | 60-40 |
| Parallelism: | <1arcmin |
| Clear aperture: | >D16mm |
| Chamfer: | 0.25mmx45deg |
| Coating: | OD2+/-0.1 at 546nm |
| Maximum OD:2.8OD | |
| Minimum OD:1.7OD | |
| Transmission band:200-1000nm,AOI:0deg | |
| Standard: | MIL-PER-13830B |
| Parameters | Inspection Tools |
|---|---|
| Dimensions: | Mitutoyo Vernier caliper |
| Thickness: | Mitutoyo micrometer |
| Flatness: | ZYGO interferometer |
| Surface quality: | naked eye test& 15W LED cold light |
| Parallelism: | Thickness gauge |
| Chamfer: | magnifier X10& naked eye test |
| Coating: | Spectrophotometer |
What to specify when you request a quote
- Spectral target — listed as “200-1000nm,AOI:0deg”; state the centre or edge wavelength, the bandwidth and the minimum transmission in the passband.
- Blocking — listed as “2.8OD”; give the blocking range and optical density (OD) the system needs.
- Angle of incidence — listed as “0°”; interference filters shift with angle, so specify the operating angle and cone.
- Size and thickness — listed as “18.0+0.0/-0.3mm”; give outline, thickness and tolerance, and whether the filter is mounted.
- Substrate — listed as “Glass”; name the substrate glass if thermal or UV behaviour matters.
- Surface quality — listed as “60-40”; quote scratch-dig for imaging paths.
Engineering guides for this part
For material grades and coating options, see Selecting Bandpass Filter Glass for Reliable Optical Performance. For an application example, read Bandpass Filter Glass for Appliance Light Detection Modules. A related standard product is Bandpass Filter.


