Product type: Thin Film Filter. Application: Lighting, Medical, Optical, Photography. Model: Customized.
Overview
Custom Optical Filters and Dichroic Beam Splitter Prisms for Medical Optics is a beam splitter made from Customized. Listed geometry: thickness Customized. Optical / electrical data: wavelength Customized, bandwidth Customized. Typical applications: Lighting, Medical, Optical and Photography. Dimensions, material grade, coating and finish can be quoted to your drawing; the values above are the listed starting point.
Specifications
| Material | Customized |
|---|---|
| Type | Thin Film Filter |
| Shape | Customized |
| Usage | Lighting, Medical, Optical, Photography |
| Model NO. | Customized |
| Thickness Range | Customized |
| Color | Customized |
| Principle | Cut-off Filter |
| Angle of incidence | Customized |
| Central Wavelength | Customized |
| Bandwidth | Customized |
| T | Customized |
| Od | Customized |
| Over | Customized |
| Center Wavelength (CWL) | Precisely positioned with a customization accuracy of up to ±0.25nm to ensure perfect matching with the emission spectrum of light sources and detector sensitivities. |
| Peak Transmittance (Tpeak) | High-transmission dielectric coating with typical peak transmittance >90% (up to >95% for specific bands), maximizing the retention of the effective signal light. |
| Bandwidth (FWHM) | Available in a wide range of options, from ultra-narrow band (<3nm), narrow band (3-20nm) to broadband (>20nm), catering to different spectral resolution requirements. |
| Warranty Period | 2 Years |
| Technology | Free technical support and solutions provided |
| Supplier | Shanghai Mega-9 Optoelectronic Co., Ltd. |
Technical data
| Parameter | BP1064/1K | BP532/1K | BP632/1K |
| Center Wavelength (nm) | 1064 ± 0.15 | 532 ± 0.15 | 632 ± 0.15 |
| Bandwidth (FWHM, nm) | 1.0 ± 0.2 | 1.0 ± 0.2 | 1.5 ± 0.2 |
| Peak Transmittance (%) | ≥70 | ≥ 75 | ≥ 80 |
| Blocking Depth (OD) | OD5 | OD6 | OD6 |
| Surface Quality (S/D) | 60-40 | 60-40 | 60-40 |
| Operating Temp. (°C) | -40 ~ +85 | -40 ~ +85 | -40 ~ +85 |
| Dimensions (mm) | 25.4 *1.0 | 25.4 *1.0 | 25.4 *1.0 |
What to specify when you request a quote
- Split ratio — give the R/T ratio and its tolerance.
- Wavelength and polarisation — listed as “Customized”; state the band and whether the split must be polarising or non-polarising.
- Angle of incidence — listed as “Customized”; plate splitters are usually used at 45°; give the actual angle.
- Size and geometry — listed as “Customized”; give cube edge or plate size, thickness and wedge if any.
- Surface quality and flatness — quote transmitted wavefront for imaging systems.
Engineering guides for this part
For material grades and coating options, see Dichroic Filter Glass: Selecting Substrates for Precision Optical Separation. For an application example, read Dichroic Filter Glass for Smart Appliance Lighting Modules. A related standard product is Dichroic Filter.